Managing a network of sites? One monitoring system for every location. [Request a quote ➡️]

PoE temperature sensor for rack cabinets: how it works and what to check before you buy
PoE temperature sensor for rack cabinets: how it works and what to check before you buy
  • 802.3af (PoE) supplies 15.4 W at the switch port and guarantees 12.95 W at the device. An environmental logger needs a fraction of that, so any PoE port will do.
  • The sensor lives on the LAN like any other host: built-in web page, SNMP read, JSON or XML over HTTP. No driver, no software.
  • Check five things before buying: standard, alarm channel independent of the cloud, number of sensor inputs, probe length, and what happens when the switch loses power.
  • The UPS that feeds the switch also feeds the sensor. Put the PoE switch on the UPS, and the logger keeps reporting through the outage.
read more »
Laboratory fridge and freezer temperature monitoring: probes, alarm delays and records that survive an audit
Laboratory Fridge and Freezer Temperature Monitoring — Probes, Alarms, Records
  • Use a buffered probe: a sensor in a glycol vial or aluminium block reads the temperature of the contents, not of the air that swings 5 °C every time the door opens.
  • Log at 30-minute intervals or shorter, with ±0.5 °C accuracy and a calibration certificate. Both the CDC and EU GDP expect this.
  • Set an alarm delay of 15–30 minutes on the warning threshold. Door openings then never wake anyone; a failed compressor still does within the hour.
  • Records must be exportable and retained: the auditor wants the chart for the week the freezer failed, not a signed sheet saying it was fine.
read more »
Server rack and network closet temperature: what is too hot, and how to monitor a rack without air conditioning
Server Rack & Network Closet Temperature — Limits and Monitoring
  • ASHRAE class A1 equipment is designed for an inlet of 18–27 °C recommended and 15–32 °C allowable. Measure at the inlet, not on the wall.
  • A closed rack in a closet without cooling can run 10–15 °C hotter at the top than at the floor. One sensor at the top front is the minimum that tells the truth.
  • The UPS battery is the first thing to die: VRLA batteries are rated at 20–25 °C and lose half their life for each 8 °C above that.
  • Power problems cause 45 % of serious outages and cooling 19 % (Uptime Institute 2025). In a small closet the two are the same failure.
read more »