Chip Electronics – systemy monitoringu środowiska dla firm
Basket
Zamknij
Continue shopping ZAMAWIAM
total: €0.00
Ulubione produkty
Lista ulubionych jest pusta.

Wybierz coś dla siebie z naszej aktualnej oferty lub zaloguj się, aby przywrócić dodane produkty do listy z poprzedniej sesji.

Search
Menu

Managing a network of sites? One monitoring system for every location. [Request a quote ➡️]

Microclimate Monitoring Kit for Museums and Archives

Gross price: €513.37
incl. 23.00% TAX, excl. shipping costs

Regular price:

513.37
The lowest price during 30 days prior to the reduction:
Net price: €417.38
excl. 23.00% TAX, excl. shipping costs

Regular price:

The lowest price during 30 days prior to the reduction:
quantity bundle
You gain 2,240 points [?]

product unavailable

Vendor: EnviSensor
Product code: ZEST-MUZ-ARCHIWUM-RS485

Bundled products

To add bundle to the basket, select all the required variants of each item.

EnviSensor RS Gate: RS485 Ethernet gateway for sensors with Cloud software

EnviSensor RS Gate: RS485 Ethernet gateway for sensors with Cloud software see gallery (20)
EnviSensor RS Gate: RS485 Ethernet gateway for sensors with Cloud software

Vendor: EnviSensor

Quantity in bundle: 1 pcs

The price of product outside the bundle €171.89

Cheaper in the bundle!

  • Operation: Locally on your LAN or via the CE MonitorApp cloud — you choose
  • Interface: Ethernet + RS-485 (up to 31 sensors, bus length up to 1200 m)
  • Data view: HTTP GET/XML, Modbus TCP, SNMP (read) — Zabbix, BMS
  • Alarms: E-mail from the device; SMS/push in paid CE MonitorApp plans
  • Sensors: Temperature, humidity — via the RS-485 bus
choose Czujnik w zestawie







choose Uchwyt montażowy



choose Certyfikat PCA


choose Zasilacz do kabla USB


TQS4 I - indoor thermometer with RS485

TQS4 I - indoor thermometer with RS485 see gallery (16)
TQS4 I - indoor thermometer with RS485

Vendor: Papouch

Quantity in bundle: 2 pcs

The price of product outside the bundle €65.78

Cheaper in the bundle!

  • Function: digital thermometer, indoor version
  • Measuring range: -40°C to +125°C
  • Supply voltage: up to 36 V
  • Housing: with ventilation openings
  • Interface: RS485
  • Protocols: Modbus RTU or Spinel

THCO2 - CO2 sensor, thermometer and hygrometer with RS485

THCO2 - CO2 sensor, thermometer and hygrometer with RS485 see gallery (15)
THCO2 - CO2 sensor, thermometer and hygrometer with RS485

Vendor: Papouch

Quantity in bundle: 1 pcs

The price of product outside the bundle €285.56

Cheaper in the bundle!

  • Function: CO2 concentration, temperature and humidity sensor
  • Temperature range: -40 to +70°C
  • CO2 range: 0 to 10,000 ppm
  • Interface: RS485
  • Protocols: Modbus RTU or Spinel
  • Software: Modbus Configurator for switching the protocol and parameters

Microclimate Monitoring Kit for Museums and Archives

The kit monitors temperature and humidity in museum rooms and archives, with an alarm when conservation standards are exceeded (humidity 45-55%).

A kit for back-of-house areas where cabling is allowed and a low cost per measuring point matters. Two TQS4 I thermometers watch the shelving zones, the THCO2 measures CO2, temperature and humidity in the public reading room, and the Polish-made EnviSensor RS Gate presents everything locally: web interface, JSON/XML, SNMP Get. The CE MonitorApp cloud is included, but optional.

Three operating modes — you choose

1. Locally, without the cloud

The gateway presents all sensors on the bus on its built-in web page on your LAN. Data via HTTP GET (JSON/XML) and SNMP Get, e-mail alarms directly from the device — no account needed.

2. On-premise with a monitoring system

Ready-made Zabbix templates — integration in 15 minutes. You can also read the bus directly using the Modbus RTU protocol.

3. CE MonitorApp cloud — included, but optional

The CE MonitorApp cloud is included in the kit — Free access with no time limit and no fees. It adds real value when you need access from outside your local network or want several locations in one dashboard. But using it is entirely optional: you don't log in, you don't create an account and you lose nothing — the devices work exactly the same locally. One device, two paths — you can choose at any time. SMS notifications and longer history are available in optional paid plans (from PLN 180 net/year).

No cloud? This kit works 100% within your network

You don't need to create an account, register devices or let traffic out of your network. Configuration, data view and alarms all work locally: the built-in web interface on your LAN, data readout via HTTP GET (JSON/XML) and SNMP Get, and e-mail alarms sent directly from the device. If your IT department does not allow cloud solutions, this kit meets that requirement without compromise.

Integration with your software

You can retrieve data directly from the devices via HTTP GET (JSON/XML) and via SNMP (read) — for your own reports, documentation and Zabbix/BMS/SCADA systems, without going through the cloud.

Gateway EnviSensor RS Gate — Ethernet 10/100 (DHCP)
Bus RS485 — add more sensors without new cabling
Zones 2× TQS4 I (temperature) + THCO2 (CO2, temp, humidity)
Data view web page · JSON/XML (HTTP GET) · SNMP Get · CE MonitorApp optional
Warranty 60 months (RS Gate)
Made in EnviSensor — Poland

Specification

  • Gateway: EnviSensor RS Gate, Ethernet 10/100, DHCP

  • 2× TQS4 I: indoor thermometer with RS485

  • THCO2: CO2 + temperature + humidity, RS485

  • Data view: web page, JSON/XML (HTTP GET)

  • SNMP: read (Get)

  • Cloud: CE MonitorApp — included, optional

Kit contents

  • EnviSensor RS Gate — RS485/Ethernet gateway × 1

  • Papouch TQS4 I — indoor RS485 thermometer (shelving zones) × 2

  • THCO2 — RS485 CO2 sensor, thermometer and hygrometer (reading room) × 1

  • CE MonitorApp — included, optional

Cost of each additional point = one sensor

In an archive, humidity and temperature determine how long records will last, and CO2 in the reading room determines how long people can work there with documents. Adding another point costs just one TQS4 I thermometer, because the bus is already in place. Flooding or mold in a single shelving zone is a loss that cannot be priced — records have no duplicates.

Example applications

Archive, collection storeroom, library, reading room.

Pre-shipment configuration

You can order the kit with alarm thresholds and network addressing already configured for your network — just take it out of the box and plug it in. We provide remote help with the first start-up. Also available for rent (MaaS) with monthly billing.

Shipping costs The price does not include any possible payment costs

Shipping country:
Microclimate Monitoring Kit for Museums and Archives Choose product variants (1/3)
Holder up